MC2A301AR6 Mini Contactor 3NO AUX 1NC 220-230V 50/60Hz

Description

The MC2A301AR6 mini contactor is a dimension optimized 3 pole contactor with 1 NC auxiliary contact and special screw terminals for a connection with ring tongue ferrules. This device is a great solution when high performances are needed but the space is limited. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. The product is suitable for wall or rail mounting.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Mini Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 1SAL102176R9902.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.17 KG / psc.
Commodity number85365080
Country of origin
Dimensions (WxHxD)45x48x56 mm
EAN code4013614545719
Product groupSM
eclassV11.0 : 27371003
etim 5EC000066 - Magnet contactor, AC-switching
etim 6EC000066 - Power contactor, AC switching
etim 7EC000066 - Power contactor, AC switching
etim 8EC000066 - Power contactor, AC switching
unspsc39121529
standardsIEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1UL 60947-5-1
power lossat Rated Operating Conditions AC-1 per Pole 0.7 W
rohs statusFollowing EU Directive 2011/65/EU
bv certificatehttps://library.abb.com/d/1SAA971000-0201
cb certificatehttps://library.abb.com/d/1SAA971000-2001
cqc certificatehttps://library.abb.com/d/CQC2019010304197131
number of poles3
rina certificatehttps://library.abb.com/d/1SAA971001-0801
rohs informationhttps://library.abb.com/d/1SAD938503-0305
culus certificatehttps://library.abb.com/d/cUL_E191658
tightening torqueAuxiliary Circuit 0.8 ... 1.0 N·mControl Circuit 0.8 N·mMain Circuit 0.8 ... 1.0 N·m
e-number (finland)3709574
mini contactor typeMini Contactor
rated frequency (f)Auxiliary Circuit 50 HzAuxiliary Circuit 60 HzAuxiliary Circuit DCControl Circuit 50 HzControl Circuit 60 HzMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC
degree of protectionAuxiliary Circuit Terminals IP20Control Circuit Terminals IP20Main Circuit Terminals IP20
mounting on din railTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
coil operating limits(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
contact rating ul/csaA600Q600
mechanical durability10000000 cycle
wire stripping lengthAuxiliary Circuit 9 mmControl Circuit 9 mmMain Circuit 9 mm
ambient air temperatureOperation -40 ... +70 °CStorage -55 ... +80 °C
full load amps motor use(115 V AC) Single Phase 9.8 A(200 V AC) Three Phase 11 A(220 ... 240 V AC) Three Phase 9.6 A(230 V AC) Single Phase 12 A(440 ... 480 V AC) Three Phase 11 A(550 ... 600 V AC) Three Phase 11 A
horsepower rating ul/csa(115 V AC) Single Phase 0.5 Hp(200 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 3 Hp(230 V AC) Single Phase 2 Hp(440 ... 480 V AC) Three Phase 7.5 Hp(550 ... 600 V AC) Three Phase 10 Hp
recommended screw driverPozidriv 2
tightening torque ul/csaAuxiliary Circuit 7 in·lbControl Circuit 7 in·lbMain Circuit 7 in·lb
environmental informationhttps://library.abb.com/d/1SAC200150H0001
general use rating ul/csa(600 V AC) 20 A
rated operational voltageAuxiliary Circuit 690 V ACAuxiliary Circuit 440 V DCMain Circuit 690 V ACMain Circuit 440 V DC
minimum switching capacityAuxiliary Circuit 17 VAuxiliary Circuit 5 mA
number of main contacts nc0
number of main contacts no3
object classification codeQ
rated insulation voltage (ui)750 V
declaration of conformity - cehttps://library.abb.com/d/1SAD938503-0305
declaration of conformity - ccchttps://library.abb.com/d/2020980304001602
number of auxiliary contacts nc1
number of auxiliary contacts no0
connecting capacity main circuitFlexible 1/2x 0.75 ... 2.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
declaration of conformity - ukcahttps://library.abb.com/d/1SAD938501-1305
maximum operating voltage ul/csaMain Circuit 600 V AC
rated operational power ac-3 (pe)(230 V) Three Phase 3 kW(400 V) Three Phase 5.5 kW(500 V) Three Phase 5.5 kW(690 V) Three Phase, NO 4 kW
rated control circuit voltage (uc)220 ... 230 V AC
connecting capacity control circuitFlexible 1/2x 0.75 ... 2.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
rated operational current ac-1 (ie)(690 V) 55 °C 20 A(690 V) 70 °C 16 A(230 V) 55 °C 20 A(230 V) 70 °C 16 A(400 V) 55 °C 20 A(400 V) 70 °C 16 A(500 V) 55 °C 20 A(500 V) 70 °C 16 A
rated operational current ac-15 (ie)(240 V) 6 A(400 V) 4 A(500 V) 2.5 A(690 V) 1.5 A
rated operational current dc-13 (ie)(24 V) 5 A(48 V) 2.5 A(125 V) 0.55 A(250 V) 0.3 A(440 V) 0.15 A
connecting capacity auxiliary circuitFlexible 1/2x 0.75 ... 2.5 mm2Rigid 1/2x 0.75 ... 2.5 mm2
maximum electrical switching frequency(AC-1) 300 cycles per hour(AC-15) 360 cycles per hour(AC-3) 1200 cycles per hour(DC-1) 600 cycles per hour(DC-13) 360 cycles per hour(DC-3) 600 cycles per hour
maximum operating altitude permissible3000 m
rated impulse withstand voltage (uimp)Auxiliary Circuit 6 kVMain Circuit 6 kV
connecting capacity main circuit ul/csaStranded 1/2x 18-12 AWG
resistance to shock acc. to iec 60068-2-2711 ms Pulse 25g
conventional free-air thermal current (ith)Auxiliary Circuit 10 AMain Circuit 20 A
connecting capacity auxiliary circuit ul/csaStranded 1/2x 18-12 AWG
resistance to vibrations acc. to iec 60068-2-65g / 3 ... 150 Hz
rated short-time withstand current low voltage (icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A

We use cookies