Product type: MS132-0.4KB
MS132-0.4KB Manual Motor Starter
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.256 KG / psc. |
Commodity number | 85362010 |
Country of origin | |
Dimensions (WxHxD) | 112x45x87 mm |
EAN code | 4013614534935 |
Product group | |
eclass | V11.0 : 27370401 |
etim 5 | EC000074 - Motor protective circuit-breaker |
etim 6 | EC000074 - Motor protection circuit-breaker |
etim 7 | EC000074 - Motor protection circuit-breaker |
etim 8 | EC000074 - Motor protection circuit-breaker |
unspsc | 39121521 |
remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K |
standards | IEC 60077-1 (applicable parts)IEC 60077-2 (applicable parts)IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1 |
rohs status | Following EU Directive 2011/65/EU |
actuator type | Rotary Handle |
setting range | 0.25 ... 0.40 A |
terminal type | Push-in Spring Terminals |
kc certificate | https://library.abb.com/d/1SAA963002-1502 |
cul certificate | https://library.abb.com/d/cUL_E137861 |
marketing video | https://library.abb.com/d/2CDC131130V0201 |
number of poles | 3 |
pollution degree | 3 |
rohs information | https://library.abb.com/d/1SAD938506-0197 |
locked rotor amps | (200 V AC) Three Phase 2.4 A(208 V AC) Three Phase 2.4 A(220 ... 240 V AC) Three Phase 2.4 A(440 ... 480 V AC) Three Phase 2.4 A(550 ... 600 V AC) Three Phase 2.4 A |
mounting position | 1 ... 6 |
i2t characteristic | https://library.abb.com/d/1SAM300507F0001, https://library.abb.com/d/1SAM300507F0003 |
rated frequency (f) | Main Circuit 50 HzMain Circuit 60 Hz |
degree of protection | Housing IP20Main Circuit Terminals IP20 |
mounting on din rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
electrical durability | 50000 cycle |
mechanical durability | 100000 cycle |
wire stripping length | Main Circuit 12 mm |
ambient air temperature | Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C |
full load amps motor use | (200 V AC) Three Phase 0.4 A(208 V AC) Three Phase 0.4 A(220 ... 240 V AC) Three Phase 0.4 A(440 ... 480 V AC) Three Phase 0.4 A(550 ... 600 V AC) Three Phase 0.4 A |
environmental information | https://library.abb.com/d/1SAC200050H0009 |
general use rating ul/csa | (600 V AC) 0.4 A |
minimum mounting distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm |
rated operational voltage | Main Circuit 690 V ACMain Circuit 250 V DC |
object classification code | F |
contact position indication | ON / OFF / TRIP |
rated insulation voltage (ui) | 690 V |
cut-off current characteristic | https://library.abb.com/d/1SAM300508F0001, https://library.abb.com/d/1SAM300508F0003 |
declaration of conformity - ce | https://library.abb.com/d/1SAD101100-3407 |
rated operational current (ie) | 0.4 A |
connecting capacity main circuit | Flexible with Ferrule 1/2x 0.5 ... 4 mm2Flexible with Insulated Ferrule 1x 0.5 ... 4 mm2Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm2Flexible 1/2x 0.75 ... 4 mm2Solid 1/2x 1 ... 2.5 mm2Stranded 1/2x 1 ... 6 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/1SAD201100-3407 |
maximum operating voltage ul/csa | Main Circuit 600 V AC |
data sheet, technical information | https://library.abb.com/d/2CDC131021D0201 |
rated operational power ac-3 (pe) | (400 V) Three Phase 0.09 kW |
time-current characteristic curve | https://library.abb.com/d/1SAM300505F0103 |
idea granular category code (igcc) | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
rated operational power ac-3e (pe) | (400 V) Three Phase 0.09 kW |
rated operational current ac-3 (ie) | 0.4 A |
rated operational current dc-5 (ie) | 0.4 A |
short-circuit current rating (sccr) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kAManual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA |
ambient air temperature compensation | Yes |
rated operational current ac-3e (ie) | 0.4 A |
maximum operating altitude permissible | 2000 m |
rated impulse withstand voltage (uimp) | Main Circuit 6 kV |
connecting capacity main circuit ul/csa | Stranded 1/2x 18-10 AWGStranded 1x 8 AWG |
resistance to shock acc. to iec 60068-2-27 | 11 ms Pulse 25g |
conventional free-air thermal current (ith) | Main Circuit 0.4 A |
resistance to vibrations acc. to iec 60068-2-6 | 5g / 3 ... 150 Hz |
rated service short-circuit breaking capacity (ics) | (230 V AC) 100 kA(250 V DC) 3 Poles in Series 10 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA |
rated ultimate short-circuit breaking capacity (icu) | (230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 100 kA(500 V AC) 100 kA(690 V AC) 100 kA |
rated instantaneous short-circuit current setting (ii) | 5 A |