Product type: EF96-100
EF96-100 Electronic Overload Relay
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.802 KG / psc. |
Commodity number | 85364900 |
Country of origin | CN |
Dimensions (WxHxD) | 70x132.7x105.2 mm |
EAN code | 4013614442247 |
Product group | SE |
eclass | V11.0 : 27371502 |
etim 4 | EC001080 - Electronic overload relay |
etim 5 | EC001080 - Electronic overload relay |
etim 6 | EC001080 - Electronic overload relay |
etim 7 | EC001080 - Electronic overload relay |
etim 8 | EC001080 - Electronic overload relay |
unspsc | 39121520 |
standards | IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1 |
power loss | at Rated Operating Conditions per Pole 0.117 ... 0.9 W |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
suitable for | AF80AF96 |
setting range | 36 ... 100 A |
bv certificate | https://library.abb.com/d/1SAA941002-0201 |
cb certificate | https://library.abb.com/d/1SAA942013-2001 |
lr certificate | https://library.abb.com/d/1SAA941002-0501 |
ul certificate | https://library.abb.com/d/E48139-19990512 |
abs certificate | https://library.abb.com/d/1SAA941002-0102 |
ccs certificate | https://library.abb.com/d/1SAA941001-0901 |
cqc certificate | https://library.abb.com/d/CQC2013010309592132 |
dnv certificate | https://library.abb.com/d/1SAA941003-0302 |
eac certificate | https://library.abb.com/d/1SAA941003-2701 |
number of poles | 3 |
atex certificate | https://library.abb.com/d/1SAA941004-3901 |
pollution degree | 3 |
rina certificate | https://library.abb.com/d/RINA_ELE376813CS |
rmrs certificate | https://library.abb.com/d/1SAA941001-0701 |
rohs information | https://library.abb.com/d/1SAD938519-0180 |
dimension diagram | https://library.abb.com/d/1SAX300406F0001 |
e-number (sweden) | 3210246 |
iecex certificate | https://library.abb.com/d/1SAA941000-4001 |
mounting position | 1 ... 6 |
tightening torque | Auxiliary Circuit 0.8 ... 1.2 N·mMain Circuit 6 N·m |
e-number (finland) | 3706581 |
rated frequency (f) | Auxiliary Circuit 50 HzAuxiliary Circuit 60 HzAuxiliary Circuit DCMain Circuit 50 HzMain Circuit 60 Hz |
degree of protection | Housing IP20Main Circuit Terminals IP10 |
contact rating ul/csa | (NC:) B600(NC:) Q600(NO:) B600(NO:) Q600 |
wire stripping length | Auxiliary Circuit 9 mmMain Circuit 20 mm |
ambient air temperature | Operation -25 ... +70 °COperation Compensated -25 ... +70 °CStorage -50 ... +85 °C |
recommended screw driver | Auxiliary Circuit Pozidriv 2Main Circuit Hexagon 4 |
tightening torque ul/csa | Auxiliary Circuit 7 ... 1 in·lbMain Circuit 70 in·lb |
environmental information | https://library.abb.com/d/1SAC200099H0001 |
number of protected poles | 3 |
rated operational voltage | Auxiliary Circuit 600 V AC/DCMain Circuit 1000 V AC |
object classification code | F |
rated insulation voltage (ui) | 1000 V |
declaration of conformity - ce | https://library.abb.com/d/1SAD938519-0180 |
rated operational current (ie) | 100 A |
declaration of conformity - ccc | https://library.abb.com/d/2020980309000286 |
number of auxiliary contacts nc | 1 |
number of auxiliary contacts no | 1 |
connecting capacity main circuit | Flexible with Ferrule 2x 4 ... 35 mm2Flexible with Ferrule 1x 4 ... 50 mm2Flexible with Insulated Ferrule 2x 2 ... 35 mm2Flexible with Insulated Ferrule 1x 4 ... 50 mm2Flexible 1x 4 ... 50 mm2Flexible 2x 4 ... 35 mm2Rigid 1x 4 ... 70 mm2Rigid 2x 4 ... 35 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/1SAD938502-1180 |
maximum operating voltage ul/csa | Main Circuit 600 V AC |
data sheet, technical information | https://library.abb.com/d/2CDC107041D0201 |
time-current characteristic curve | https://library.abb.com/d/1SAX100509F0001, https://library.abb.com/d/1SAX100510F0001 |
idea granular category code (igcc) | 5364 >> Overload relay |
ambient air temperature compensation | Yes |
rated operational current ac-15 (ie) | (240 V) NC 3 A(240 V) NO 3 A(400 V) NC 1.1 A(400 V) NO 1.1 A(500 V) NC 0.75 A(500 V) NO 0.75 A |
rated operational current dc-13 (ie) | (125 V) NC 0.55 A(125 V) NO 0.5 A(24 V) NC 1.5 A(24 V) NO 1.5 A(250 V) NC 0.27 A(250 V) NO 0.27 A(60 V) NC 0.55 A(60 V) NO 0.55 A |
connecting capacity auxiliary circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm2Flexible 1/2x 0.75 ... 2.5 mm2Rigid 1/2x 1 ... 4 mm2 |
maximum operating altitude permissible | 2000 m |
rated impulse withstand voltage (uimp) | Auxiliary Circuit 6 kVMain Circuit 8 kV |
connecting capacity main circuit ul/csa | Flexible 1/2x 10-2 AWGStranded 1/2x 10-2 AWG |
resistance to shock acc. to iec 60068-2-27 | 11 ms Pulse 25g |
conventional free-air thermal current (ith) | Auxiliary Circuit NC 6 AAuxiliary Circuit NO 6 A |
connecting capacity auxiliary circuit ul/csa | Flexible 1/2x 18-10 AWGStranded 1/2x 18-10 AWG |
resistance to vibrations acc. to iec 60068-2-6 | 5g / 3 ... 150 Hz |
We use cookies