ABB

1SAX341001R1101

Product type: EF96-100

EF96-100 Electronic Overload Relay

Description

The EF96 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the contactors. Single mounting kits are available as accessory. The EF65, EF96 and EF146have ATEX and IECEx certification 1)1) ATEX is valid for products produced from week 42, 2014.IECEx is valid for products produced from week 15, 2017.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Electronic Overload Relays
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 1SAX341001R1101.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.802 KG / psc.
Commodity number85364900
Country of originCN
Dimensions (WxHxD)70x132.7x105.2 mm
EAN code4013614442247
Product groupSE
eclassV11.0 : 27371502
etim 4EC001080 - Electronic overload relay
etim 5EC001080 - Electronic overload relay
etim 6EC001080 - Electronic overload relay
etim 7EC001080 - Electronic overload relay
etim 8EC001080 - Electronic overload relay
unspsc39121520
standardsIEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1
power lossat Rated Operating Conditions per Pole 0.117 ... 0.9 W
rohs statusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
suitable forAF80AF96
setting range36 ... 100 A
bv certificatehttps://library.abb.com/d/1SAA941002-0201
cb certificatehttps://library.abb.com/d/1SAA942013-2001
lr certificatehttps://library.abb.com/d/1SAA941002-0501
ul certificatehttps://library.abb.com/d/E48139-19990512
abs certificatehttps://library.abb.com/d/1SAA941002-0102
ccs certificatehttps://library.abb.com/d/1SAA941001-0901
cqc certificatehttps://library.abb.com/d/CQC2013010309592132
dnv certificatehttps://library.abb.com/d/1SAA941003-0302
eac certificatehttps://library.abb.com/d/1SAA941003-2701
number of poles3
atex certificatehttps://library.abb.com/d/1SAA941004-3901
pollution degree3
rina certificatehttps://library.abb.com/d/RINA_ELE376813CS
rmrs certificatehttps://library.abb.com/d/1SAA941001-0701
rohs informationhttps://library.abb.com/d/1SAD938519-0180
dimension diagramhttps://library.abb.com/d/1SAX300406F0001
e-number (sweden)3210246
iecex certificatehttps://library.abb.com/d/1SAA941000-4001
mounting position1 ... 6
tightening torqueAuxiliary Circuit 0.8 ... 1.2 N·mMain Circuit 6 N·m
e-number (finland)3706581
rated frequency (f)Auxiliary Circuit 50 HzAuxiliary Circuit 60 HzAuxiliary Circuit DCMain Circuit 50 HzMain Circuit 60 Hz
degree of protectionHousing IP20Main Circuit Terminals IP10
contact rating ul/csa(NC:) B600(NC:) Q600(NO:) B600(NO:) Q600
wire stripping lengthAuxiliary Circuit 9 mmMain Circuit 20 mm
ambient air temperatureOperation -25 ... +70 °COperation Compensated -25 ... +70 °CStorage -50 ... +85 °C
recommended screw driverAuxiliary Circuit Pozidriv 2Main Circuit Hexagon 4
tightening torque ul/csaAuxiliary Circuit 7 ... 1 in·lbMain Circuit 70 in·lb
environmental informationhttps://library.abb.com/d/1SAC200099H0001
number of protected poles3
rated operational voltageAuxiliary Circuit 600 V AC/DCMain Circuit 1000 V AC
object classification codeF
rated insulation voltage (ui)1000 V
declaration of conformity - cehttps://library.abb.com/d/1SAD938519-0180
rated operational current (ie)100 A
declaration of conformity - ccchttps://library.abb.com/d/2020980309000286
number of auxiliary contacts nc1
number of auxiliary contacts no1
connecting capacity main circuitFlexible with Ferrule 2x 4 ... 35 mm2Flexible with Ferrule 1x 4 ... 50 mm2Flexible with Insulated Ferrule 2x 2 ... 35 mm2Flexible with Insulated Ferrule 1x 4 ... 50 mm2Flexible 1x 4 ... 50 mm2Flexible 2x 4 ... 35 mm2Rigid 1x 4 ... 70 mm2Rigid 2x 4 ... 35 mm2
declaration of conformity - ukcahttps://library.abb.com/d/1SAD938502-1180
maximum operating voltage ul/csaMain Circuit 600 V AC
data sheet, technical informationhttps://library.abb.com/d/2CDC107041D0201
time-current characteristic curvehttps://library.abb.com/d/1SAX100509F0001, https://library.abb.com/d/1SAX100510F0001
idea granular category code (igcc)5364 >> Overload relay
ambient air temperature compensationYes
rated operational current ac-15 (ie)(240 V) NC 3 A(240 V) NO 3 A(400 V) NC 1.1 A(400 V) NO 1.1 A(500 V) NC 0.75 A(500 V) NO 0.75 A
rated operational current dc-13 (ie)(125 V) NC 0.55 A(125 V) NO 0.5 A(24 V) NC 1.5 A(24 V) NO 1.5 A(250 V) NC 0.27 A(250 V) NO 0.27 A(60 V) NC 0.55 A(60 V) NO 0.55 A
connecting capacity auxiliary circuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm2Flexible 1/2x 0.75 ... 2.5 mm2Rigid 1/2x 1 ... 4 mm2
maximum operating altitude permissible2000 m
rated impulse withstand voltage (uimp)Auxiliary Circuit 6 kVMain Circuit 8 kV
connecting capacity main circuit ul/csaFlexible 1/2x 10-2 AWGStranded 1/2x 10-2 AWG
resistance to shock acc. to iec 60068-2-2711 ms Pulse 25g
conventional free-air thermal current (ith)Auxiliary Circuit NC 6 AAuxiliary Circuit NO 6 A
connecting capacity auxiliary circuit ul/csaFlexible 1/2x 18-10 AWGStranded 1/2x 18-10 AWG
resistance to vibrations acc. to iec 60068-2-65g / 3 ... 150 Hz