Product type: TF42-1.0
TF42-1.0 Thermal Overload Relay
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.13 KG / psc. |
Commodity number | 85364900 |
Country of origin | DE |
Dimensions (WxHxD) | 45x88.3x70.5 mm |
EAN code | 4013614398049 |
Product group | SE |
eclass | V11.0 : 27371501 |
etim 4 | EC000106 - Thermal overload relay |
etim 5 | EC000106 - Thermal overload relay |
etim 6 | EC000106 - Thermal overload relay |
etim 7 | EC000106 - Thermal overload relay |
etim 8 | EC000106 - Thermal overload relay |
unspsc | 39121520 |
standards | IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1 |
power loss | at Rated Operating Conditions per Pole 1.1 ... 2.0 W |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
suitable for | AF09AF12AF16AF26AF30AF38 |
setting range | 0.74 ... 1.0 A |
bv certificate | https://library.abb.com/d/1SAA941001-0203 |
cb certificate | https://library.abb.com/d/1SAA941009-2001 |
gl certificate | https://library.abb.com/d/1SAA941007-0401 |
lr certificate | https://library.abb.com/d/1SAA941001-0502 |
ul certificate | https://library.abb.com/d/E48139-20090126 |
abs certificate | https://library.abb.com/d/1SAA941001-0102 |
cqc certificate | https://library.abb.com/d/CQC2011010309464423 |
eac certificate | https://library.abb.com/d/1SAA941002-2701 |
number of poles | 3 |
atex certificate | https://library.abb.com/d/1SAA941001-3901 |
pollution degree | 3 |
rina certificate | https://library.abb.com/d/1SAA941000-0802 |
rmrs certificate | https://library.abb.com/d/1SAA941000-0704 |
rohs information | https://library.abb.com/d/1SAD938513-0181 |
dimension diagram | https://library.abb.com/d/1SAZ700405F0001 |
e-number (sweden) | 3211961 |
iecex certificate | https://library.abb.com/d/1SAA941003-4001 |
tightening torque | Auxiliary Circuit 1 ... 1.5 N·mMain Circuit 1.5 ... 2.5 N·m |
dnv gl certificate | https://library.abb.com/d/1SAA941001-0302 |
e-number (finland) | 3706117 |
rated frequency (f) | Auxiliary Circuit 50 HzAuxiliary Circuit 60 HzAuxiliary Circuit DCMain Circuit 50 HzMain Circuit 60 Hz |
ampere rating ul/csa | 1 A |
degree of protection | IP20 |
contact rating ul/csa | (NC:) B600(NC:) Q600(NO:) Q600(NO:) D300 |
wire stripping length | Auxiliary Circuit 9 mmMain Circuit 12 mm |
ambient air temperature | Operation -25 ... +60 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C |
recommended screw driver | Main Circuit Pozidriv 2 |
tightening torque ul/csa | Auxiliary Circuit 9 ... 13 in·lbMain Circuit 13 ... 22 in·lb |
environmental information | https://library.abb.com/d/1SAC200057H0009 |
number of protected poles | 3 |
rated operational voltage | Auxiliary Circuit 600 V AC/DCMain Circuit 690 V ACMain Circuit 600 V DC |
object classification code | F |
rated insulation voltage (ui) | 690 V |
declaration of conformity - ce | https://library.abb.com/d/1SAD938513-0181 |
rated operational current (ie) | 1 A |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001788 |
number of auxiliary contacts nc | 1 |
number of auxiliary contacts no | 1 |
connecting capacity main circuit | Flexible with Ferrule 1/2x 0.75 ... 4 mm2Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm2Flexible 1/2x 0.75 ... 4 mm2Rigid 1/2x 0.75 ... 4 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/1SAD938501-1181 |
maximum operating voltage ul/csa | Main Circuit 600 V AC |
data sheet, technical information | https://library.abb.com/d/2CDC106023D0201 |
time-current characteristic curve | https://library.abb.com/d/1SAZ700506F0008 |
idea granular category code (igcc) | 5364 >> Overload relay |
ambient air temperature compensation | Yes |
rated operational current ac-15 (ie) | (120 V) NC 3 A(120 V) NO 0.5 A(240 V) NC 3 A(240 V) NO 0.5 A(400 V) NC 0.75 A(400 V) NO 0.5 A(500 V) NC 0.75 A(500 V) NO 0.5 A |
rated operational current dc-13 (ie) | (125 V) NC 0.55 A(125 V) NO 0.55 A(24 V) NC 1.25 A(24 V) NO 1.25 A(250 V) NC 0.27 A(250 V) NO 0.27 A(500 V) NC 0.15 A(500 V) NO 0.15 A(60 V) NC 0.55 A(60 V) NO 0.55 A |
connecting capacity auxiliary circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm2Flexible 1/2x 0.75 ... 1 mm2Flexible 1/2x 1 ... 2.5 mm2Rigid 1/2x 0.75 ... 4 mm2 |
maximum operating altitude permissible | 2000 m |
rated impulse withstand voltage (uimp) | Auxiliary Circuit 6 kVMain Circuit 6 kV |
connecting capacity main circuit ul/csa | Flexible 1/2x 18-10 AWGStranded 1/2x 18-10 AWG |
resistance to shock acc. to iec 60068-2-27 | 11 ms Pulse 25g |
conventional free-air thermal current (ith) | Auxiliary Circuit NC 6 AAuxiliary Circuit NO 4 A |
connecting capacity auxiliary circuit ul/csa | Flexible 1/2x 18-12 AWGStranded 1/2x 18-12 AWG |
resistance to vibrations acc. to iec 60068-2-6 | 5g / 3 ... 150 Hz |