Product type: AF26-30-00K-12
AF26-30-00K-12 48-130V50/60HZ-DC Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.325 KG / psc. |
Commodity number | 85364900 |
Country of origin | FR |
Dimensions (WxHxD) | 45x92.3x86 mm |
EAN code | 3471523154926 |
Product group | SB |
eclass | V11.0 : 27371003 |
etim 4 | EC000066 - Magnet contactor, AC-switching |
etim 5 | EC000066 - Magnet contactor, AC-switching |
etim 6 | EC000066 - Power contactor, AC switching |
etim 7 | EC000066 - Power contactor, AC switching |
etim 8 | EC000066 - Power contactor, AC switching |
unspsc | 39121529 |
nema size | 1 |
rohs status | Following EU Directive 2011/65/EU |
operate time | Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms |
terminal type | Push-in Spring Terminals |
cb certificate | https://library.abb.com/d/CB_SE-96552M1 |
gl certificate | https://library.abb.com/d/DNV-GL_TAE00001AF-3 |
abs certificate | https://library.abb.com/d/ABS_20-2060694-PDA |
ccc certificate | https://library.abb.com/d/CCC_2010010304445623 |
cqc certificate | https://library.abb.com/d/CQC2010010304445623, https://library.abb.com/d/CQC2020010304294316 |
cul certificate | https://library.abb.com/d/UL_20180227_E312527_7_1 |
rina certificate | https://library.abb.com/d/RINA_ELE240318XG |
rmrs certificate | https://library.abb.com/d/RMRS_1802705280 |
rohs information | https://library.abb.com/d/1SBD250000U1000 |
dimension diagram | https://library.abb.com/d/DNV_TAE00001AF-4 |
e-number (sweden) | 3210614 |
climatic withstand | Category B according to IEC 60947-1 Annex Q |
e-number (finland) | 3707894 |
rated frequency (f) | Main Circuit 50 / 60 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
mounting on din rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
wire stripping length | Control Circuit 10 mmMain Circuit 14 mm |
horsepower rating nema | (115 V AC) Single Phase 2 Hp(200 V AC) Three Phase 7-1/2 Hp(230 V AC) Single Phase 3 Hp(230 V AC) Three Phase 7-1/2 Hp(460 V AC) Three Phase 10 Hp(575 V AC) Three Phase 10 Hp |
ambient air temperature | Close to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C |
horsepower rating ul/csa | (120 V AC) Single Phase 2 hp(200 ... 208 V AC) Three Phase 7-1/2 hp(220 ... 240 V AC) Three Phase 7-1/2 hp(240 V AC) Single Phase 3 hp(440 ... 480 V AC) Three Phase 15 hp(550 ... 600 V AC) Three Phase 20 hp |
general use rating ul/csa | (600 V AC) 42 A |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A |
rated operational voltage | Main Circuit 690 V |
number of main contacts nc | 0 |
number of main contacts no | 3 |
object classification code | Q |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V |
continuous current rating nema | 27 A |
declaration of conformity - ce | https://library.abb.com/d/1SBD250000U1000 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001254, https://library.abb.com/d/2020980304001052 |
number of auxiliary contacts nc | 0 |
number of auxiliary contacts no | 0 |
connecting capacity main circuit | Flexible with Ferrule 1/2x 1 ... 6 mm2Flexible with Insulated Ferrule 1/2x 1 ... 6 mm2Flexible 1/2x 1 ... 6 mm2Rigid 1/2x 1 ... 10 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/1SBD250031U1000 |
mounting by screws (not supplied) | 2 x M4 screws placed diagonally |
rated operational power ac-3 (pe) | (415 V) 11 kW(440 V) 15 kW(500 V) 15 kW(690 V) 15 kW(380 / 400 V) 11 kW(220 / 230 / 240 V) 6.5 kW |
rated control circuit voltage (uc) | 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V |
rated operational power ac-3e (pe) | (415 V) 11 kW(440 V) 15 kW(500 V) 15 kW(690 V) 15 kW(380 / 400 V) 11 kW(220 / 230 / 240 V) 6.5 kW |
connecting capacity control circuit | Flexible with Ferrule 1/2x 0.5 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm2Flexible 1/2x 0.5 ... 2.5 mm2Rigid 1/2x 1 ... 2.5 mm2 |
rated operational current ac-1 (ie) | (690 V) 40 °C 45 A(690 V) 60 °C 40 A(690 V) 70 °C 32 A |
rated operational current ac-3 (ie) | (415 V) 60 °C 26 A(440 V) 60 °C 26 A(500 V) 60 °C 23 A(690 V) 60 °C 17 A(380 / 400 V) 60 °C 26 A(220 / 230 / 240 V) 60 °C 26 A |
rated operational current ac-3e (ie) | (415 V) 60 °C 26 A(440 V) 60 °C 26 A(500 V) 60 °C 23 A(690 V) 60 °C 17 A(380 / 400 V) 60 °C 26 A(220 / 230 / 240 V) 60 °C 26 A |
maximum electrical switching frequency | (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour |
maximum mechanical switching frequency | 3600 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | 6 kV |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A |
resistance to vibrations acc. to iec 60068-2-6 | 5 ... 300 Hz 4 g closed position / 2 g open position |
rated short-time withstand current low voltage (icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 Afor 1 s -empty- A |