Product type: UA26-30-10RA 24V 50Hz / 24V 60Hz
UA26-30-10RA 24V 50Hz / 24V 60Hz Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.71 KG / psc. |
Commodity number | 85364900 |
Country of origin | FR |
Dimensions (WxHxD) | 54x120x126.3 mm |
EAN code | 3471522301819 |
Product group | SB |
eclass | V11.0 : 27371006 |
etim 4 | EC001079 - Capacitor magnet contactor |
etim 5 | EC001079 - Capacitor magnet contactor |
etim 6 | EC001079 - Capacitor contactor |
etim 7 | EC001079 - Capacitor contactor |
etim 8 | EC001079 - Capacitor contactor |
unspsc | 39121529 |
rohs status | Following EU Directive 2011/65/EU |
operate time | Between Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NO Contact Closing 8 ... 21 ms |
terminal type | Screw Terminals |
cb certificate | https://library.abb.com/d/CB_FR3447_60016915-509739B |
ccc certificate | https://library.abb.com/d/CCC_2004010304138316 |
cqc certificate | https://library.abb.com/d/CQC2003010304060095, https://library.abb.com/d/CQC2008010304261926 |
csa certificate | https://library.abb.com/d/CSA_1033838_LR056745 |
coil consumption | Average Holding Value 50 / 60 Hz 12 V·AAverage Holding Value 50 Hz 12 V·AAverage Holding Value 60 Hz 12 V·AAverage Pull-in Value 50 Hz 120 V·AAverage Pull-in Value 60 Hz 140 V·A |
gost certificate | https://library.abb.com/d/GOST_POCCFRME77B07175 |
rohs information | https://library.abb.com/d/1SBD250805U1000 |
dimension diagram | https://library.abb.com/d/FPTE307846 |
climatic withstand | acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
rated frequency (f) | Supply Circuit 50 / 60 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
mounting on din rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
ambient air temperature | Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... 55 °CNear Contactor for Operation in Free Air (Uc) -40 ... 70 °C |
environmental information | https://library.abb.com/d/1SBD250123E1000 |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A |
rated operational voltage | Auxiliary Circuit 690 VMain Circuit 690 V |
number of main contacts nc | 0 |
number of main contacts no | 3 |
object classification code | Q |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
declaration of conformity - ce | https://library.abb.com/d/1SBD250805U1000 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001610, https://library.abb.com/d/2020980304001217 |
number of auxiliary contacts nc | 0 |
number of auxiliary contacts no | 1 |
declaration of conformity - ukca | https://library.abb.com/d/1SBD250822U1000 |
short-circuit protective devices | Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 125 A |
data sheet, technical information | https://library.abb.com/d/1SBC101140C0203 |
mounting by screws (not supplied) | 2 x M4 screws placed diagonally |
rated control circuit voltage (uc) | 50 Hz 24 V60 Hz 24 V |
rated operational power ac-6b (pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 12.5 kvar(230 / 240 V) 55 °C, 50 / 60 Hz 11.5 kvar(230 / 240 V) 70 °C, 50 / 60 Hz 9 kvar(400 / 415 V) 40 °C, 50 / 60 Hz 22 kvar(400 / 415 V) 70 °C, 50 / 60 Hz 15.5 kvar(400 / 415 V) 55 °C, 50 / 60 Hz 20 kvar(440 V) 40 °C, 50 / 60 Hz 24 kvar(440 V) 55 °C, 50 / 60 Hz 20 kvar(440 V) 70 °C, 50 / 60 Hz 17 kvar(500 / 550 V), 40 °C, 50 / 60 Hz 30 kvar(500 / 550 V) 55 °C, 50 / 60 Hz 25 kvar(500 / 550 V) 70 °C, 50 / 60 Hz 20 kvar(690 V) 40 °C, 50 / 60 Hz 35 kvar(690 V) 55 °C, 50 / 60 Hz 31 kvar(690 V) 70 °C, 50 / 60 Hz 26 kvar |
rated operational current ac-15 (ie) | (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A |
rated operational current dc-13 (ie) | (24 V) 6 / 144 A(48 V) 2.8 / 134 A(72 V) 2 / 144 A(125 V) 1.1 / 138 A(250 V) 0.55 / 138 A |
connecting capacity auxiliary circuit | Flexible with Cable End 0.75 ... 2.5 mm2Rigid Cable 1 ... 4 mm2 |
maximum electrical switching frequency | 240 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | 8 kV |
conventional free-air thermal current (ith) | acc. to IEC 60947-5-1, q = 40 °C 16 A |
connecting terminals (delivered in open position) main poles | M 4 (+,-) pozidriv 2 screws with cable clamp |