Product type: AFC38-30-00K-84
AFC38-30-00K-84 110V50Hz 110-120V60Hz Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 0.356 KG / psc. |
Commodity number | 85364900 |
Country of origin | |
Dimensions (WxHxD) | 45x92.3x86 mm |
EAN code | 3471523015111 |
Product group | SB |
eclass | V11.0 : 27371003 |
etim 6 | EC000066 - Power contactor, AC switching |
etim 7 | EC000066 - Power contactor, AC switching |
etim 8 | EC000066 - Power contactor, AC switching |
standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
operate time | Between Coil De-energization and NC Contact Closing 9 ... 20 msBetween Coil De-energization and NO Contact Opening 4 ... 18 msBetween Coil Energization and NC Contact Opening 7 ... 21 msBetween Coil Energization and NO Contact Closing 10 ... 26 ms |
terminal type | Push-in Spring Terminals |
cb certificate | https://library.abb.com/d/CB_SE-96552M1 |
ul certificate | https://library.abb.com/d/UL_20191021-E312527_7_1 |
cqc certificate | https://library.abb.com/d/CQC2010010304445623 |
rohs information | https://library.abb.com/d/1SBD251089E1000 |
climatic withstand | Category B according to IEC 60947-1 Annex Q |
rated frequency (f) | Main Circuit 50 / 60 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
mounting on din rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
wire stripping length | Control Circuit 10 mmMain Circuit 14 mm |
ambient air temperature | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 60 °CClose to Contactor without Thermal O/L Relay (Uc) -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C |
horsepower rating ul/csa | (120 V AC) Single Phase 2 hp(200 ... 208 V AC) Three Phase 10 hp(220 ... 240 V AC) Three Phase 10 hp(240 V AC) Single Phase 5 hp(440 ... 480 V AC) Three Phase 25 hp(550 ... 600 V AC) Three Phase 30 hp |
general use rating ul/csa | (600 V AC) 45 A |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A |
rated operational voltage | Main Circuit 690 V |
number of main contacts nc | 0 |
number of main contacts no | 3 |
object classification code | Q |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V |
declaration of conformity - ce | https://library.abb.com/d/1SBD250024U1000 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001254 |
number of auxiliary contacts nc | 0 |
number of auxiliary contacts no | 0 |
connecting capacity main circuit | Flexible with Ferrule 1/2x 1 ... 6 mm2Flexible with Insulated Ferrule 1/2x 1 ... 6 mm2Flexible 1/2x 1 ... 6 mm2Rigid 1/2x 1 ... 10 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/1SBD250045U1000 |
data sheet, technical information | https://library.abb.com/d/1SBC100219C0201 |
mounting by screws (not supplied) | 2 x M4 screws placed diagonally |
rated operational power ac-3 (pe) | (415 V) 18.5 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW |
rated control circuit voltage (uc) | 50 Hz 110 V60 Hz 110 ... 120 V |
rated operational power ac-3e (pe) | (415 V) 18.5 kW(440 V) 22 kW(500 V) 22 kW(690 V) 22 kW(380 / 400 V) 18.5 kW(220 / 230 / 240 V) 11 kW |
connecting capacity control circuit | Flexible with Ferrule 1/2x 0.5 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm2Flexible 1/2x 0.5 ... 2.5 mm2Rigid 1/2x 1 ... 2.5 mm2 |
rated operational current ac-1 (ie) | (690 V) 40 °C 50 A(690 V) 60 °C 42 A(690 V) 70 °C 37 A |
rated operational current ac-3 (ie) | (415 V) 60 °C 38 A(440 V) 60 °C 38 A(500 V) 60 °C 33 A(690 V) 60 °C 24 A(380 / 400 V) 60 °C 38 A(220 / 230 / 240 V) 60 °C 40 A |
rated operational current ac-3e (ie) | (415 V) 60 °C 38 A(440 V) 60 °C 38 A(500 V) 60 °C 33 A(690 V) 60 °C 24 A(380 / 400 V) 60 °C 38 A(220 / 230 / 240 V) 60 °C 40 A |
connecting capacity auxiliary circuit | Flexible 1/2x 1 ... 6 mm2Rigid 1/2x 1 ... 2.5 mm2 |
maximum electrical switching frequency | (AC-1) 600 cycles per hour(AC-15) 0 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 0 cycles per hour |
maximum mechanical switching frequency | 3600 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | 6 kV |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 Aacc. to IEC 60947-5-1, q = 40 °C 16 A |
resistance to vibrations acc. to iec 60068-2-6 | 5 ... 300 Hz 4 g closed position / 2 g open position |
rated short-time withstand current low voltage (icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 Afor 1 s -empty- A |