Weight | 20 KG / psc. |
Commodity number | 85362090 |
Country of origin | |
Dimensions (WxHxD) | 348x363.5x271 mm |
EAN code | 8015644767013 |
Product group | LA |
eclass | V11.1 : 27370409 |
etim 4 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
etim 5 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
etim 6 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
etim 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
etim 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
release | Ekip Dip LI |
version | W |
sub-type | E1.2 |
standards | IEC |
power loss | 400 W |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
current type | AC |
product name | Air Circuit Breaker |
release type | EL |
weee category | 5. Small Equipment (No External Dimension More Than 50 cm) |
wiring diagram | https://library.abb.com/d/1SDM000091R0001 |
number of poles | 4 |
rohs information | https://library.abb.com/d/9AKK108466A1424 |
product main type | SACE Emax 2 |
reach declaration | https://library.abb.com/d/9AKK108466A1425 |
rated current (in) | 1600 A |
rated voltage (ur) | 690 V |
mechanical drawings | https://library.abb.com/d/1SDH000999R0103 |
electrical durability | Ue =< 440 V 3000 cycleUe = 500 ... 690 V 6500 cycle30 cycles per hour |
mechanical durability | 20000 cycle60 cycles per hour |
order code us and canada | ZACSEJAA000A000000XX |
environmental information | https://library.abb.com/d/9AKK10103A1038 |
rated operational voltage | 690 V AC |
object classification code | Q |
neutral pole current ([%iu]) | 100 % |
rated insulation voltage (ui) | AC 1000 V |
declaration of conformity - ce | https://library.abb.com/d/9AKK106713A5546 |
short-circuit performance level | C |
rated uninterrupted current (iu) | 1600 A |
data sheet, technical information | https://library.abb.com/d/1SDC200023D0209 |
rated impulse withstand voltage (uimp) | acc. to IEC 60947-2 12 kV |
rated service short-circuit breaking capacity (ics) | (220 V AC) 50 kA(230 V AC) 50 kA(380 V AC) 50 kA(400 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 42 kA(660 V AC) 42 kA(690 V AC) 42 kA |
rated short-time withstand current low voltage (icw) | for 1 s 42 kAfor 3 s 24 kA |
rated ultimate short-circuit breaking capacity (icu) | (400 V AC) 50 kA(415 V AC) 50 kA(440 V AC) 50 kA(500 V AC) 42 kA(525 V AC) 42 kA(690 V AC) 42 kA |
rated service short-circuit breaking capacity, in % of icu (ics) | 100 % |