Product type: UA95-30-00RA-81
UA95-30-00RA 24V 50Hz Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 1.8 KG / psc. |
Commodity number | 85364900 |
Country of origin | |
Dimensions (WxHxD) | 90x170x155.6 mm |
EAN code | 7320500260418 |
Product group | SC |
eclass | V11.0 : 27371006 |
etim 4 | EC001079 - Capacitor magnet contactor |
etim 5 | EC001079 - Capacitor magnet contactor |
etim 6 | EC001079 - Capacitor contactor |
etim 7 | EC001079 - Capacitor contactor |
etim 8 | EC001079 - Capacitor contactor |
unspsc | 39121529 |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
operate time | Between Coil De-energization and NC Contact Closing 7 ... 15 msBetween Coil Energization and NO Contact Closing 10 ... 25 ms |
terminal type | Cable Clamp |
cb certificate | https://library.abb.com/d/SE-72476 |
coil consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 26 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A |
rohs information | https://library.abb.com/d/2CMT2015-005436 |
culus certificate | https://library.abb.com/d/20160916- E36588 |
rated frequency (f) | Main Circuit 50 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
coil operating limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
mechanical durability | 10 million |
ambient air temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C |
environmental information | https://library.abb.com/d/1SFC101001D0201 |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A |
rated operational voltage | Main Circuit 1000 V |
number of main contacts nc | 0 |
number of main contacts no | 3 |
object classification code | Q |
rated making capacity ac-3 | 10 x Ie AC-3 |
rated breaking capacity ac-3 | 8 x Ie AC-3 |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
declaration of conformity - ce | https://library.abb.com/d/2CMT2015-005436 |
number of auxiliary contacts nc | 0 |
number of auxiliary contacts no | 0 |
connecting capacity main circuit | Bar 30 mm2Flexible with Cable End 2 x 6 ... 35 mm2Rigid 2 x 6 ... 65 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/2CMT2020-006118 |
maximum operating voltage ul/csa | Main Circuit 600 V |
data sheet, technical information | https://library.abb.com/d/1SBC101145L0202 |
rated operational power ac-3 (pe) | (380 / 400 V) 45 kW |
idea granular category code (igcc) | 4756 >> Capacitor magnet contactor |
rated control circuit voltage (uc) | 50 Hz 24 V60 Hz 24 V |
rated operational power ac-6b (pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 40 kvar(230 / 240 V) 55 °C, 50 / 60 Hz 35 kvar(230 / 240 V) 70 °C, 50 / 60 Hz 30 kvar(400 / 415 V) 40 °C, 50 / 60 Hz 70 kvar(400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar(400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar(440 V) 40 °C, 50 / 60 Hz 75 kvar(440 V) 55 °C, 50 / 60 Hz 65 kvar(440 V) 70 °C, 50 / 60 Hz 58 kvar(500 / 550 V), 40 °C, 50 / 60 Hz 85 kvar(500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar(500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar(690 V) 40 °C, 50 / 60 Hz 120 kvar(690 V) 55 °C, 50 / 60 Hz 105 kvar(690 V) 70 °C, 50 / 60 Hz 85 kvar |
rated operational current ac-1 (ie) | (690 V) 40 °C 145 A(690 V) 55 °C 135 A(690 V) 60 °C 135 A(690 V) 70 °C 115 A |
rated operational current ac-3 (ie) | (415 V) 55 °C 96 A(440 V) 55 °C 93 A(500 V) 55 °C 80 A(690 V) 55 °C 65 A(1000 V) 55 °C 30 A(380 / 400 V) 55 °C 96 A(220 / 230 / 240 V) 55 °C 96 |
connecting capacity auxiliary circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 2x0.75 ... 2.5 mm2Solid 2 x 1 ... 4 mm2Stranded 1 x 1 .... 4 mm2 |
maximum electrical switching frequency | (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour |
maximum mechanical switching frequency | 3600 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | Main Circuit 8 kV |
resistance to shock acc. to iec 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A |
connecting terminals (delivered in open position) main poles | M8 hexagon socket screw with single connector |
We use cookies
This website collects cookies to deliver better user experience. By using our website, you agree to the use of cookies.