Product type: AF140-40-22B-14
AF140-40-22B-14 Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 1.95 KG / psc. |
Commodity number | 85364900 |
Country of origin | SE |
Dimensions (WxHxD) | 120x150x128 mm |
EAN code | 7320500505168 |
Product group | SC |
eclass | V11.0 : 27371003 |
etim 4 | EC000066 - Magnet contactor, AC-switching |
etim 5 | EC000066 - Magnet contactor, AC-switching |
etim 6 | EC000066 - Power contactor, AC switching |
etim 7 | EC000066 - Power contactor, AC switching |
etim 8 | EC000066 - Power contactor, AC switching |
unspsc | 39121529 |
nema size | 4 |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
operate time | Between Coil De-energization and NO Contact Opening 40 ... 70 msBetween Coil Energization and NO Contact Closing 20 ... 55 ms |
terminal type | Main Circuit: Bars |
bv certificate | https://library.abb.com/d/BV_36353_A0BV |
cb certificate | https://library.abb.com/d/SEMKO_SE-70479M1 |
kc certificate | https://library.abb.com/d/9AKK107046A9911 |
lr certificate | https://library.abb.com/d/LR_14_70011(E1) |
abs certificate | https://library.abb.com/d/14-LD1092198-PDA |
cqc certificate | https://library.abb.com/d/CQC2013010304604055 |
cul certificate | https://library.abb.com/d/E73397_20140710 |
eac certificate | https://library.abb.com/d/9AKK107046A8618 |
prs certificate | https://library.abb.com/d/TE_2092_880423_16 |
coil consumption | Average Pull-in Value 50 Hz 260 V·AAverage Pull-in Value 60 Hz 260 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·AHolding at Max. Rated Control Circuit Voltage DC 4 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·APull-in at Max. Rated Control Circuit Voltage DC 230 W |
rina certificate | https://library.abb.com/d/ELE060313XG_002 |
rmrs certificate | https://library.abb.com/d/9AKK107045A6978 |
rohs information | https://library.abb.com/d/2CMT2015-005440 |
dimension diagram | https://library.abb.com/d/1SFB535001G1121 |
dnv gl certificate | https://library.abb.com/d/DNV_E-14043 |
e-number (finland) | 3707178 |
rated frequency (f) | Main Circuit 50 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
coil operating limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
mechanical durability | 5 million |
ambient air temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... +70 °C |
general use rating ul/csa | (600 V AC) 200 A |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A |
rated operational voltage | Main Circuit 690 V |
number of main contacts nc | 0 |
number of main contacts no | 4 |
object classification code | Q |
rated making capacity ac-3 | 10 x Ie AC-3 |
rated breaking capacity ac-3 | 8 x Ie AC-3 |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
declaration of conformity - ce | https://library.abb.com/d/2CMT2015-005440 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001304 |
number of auxiliary contacts nc | 2 |
number of auxiliary contacts no | 2 |
connecting capacity main circuit | Flexible 1 x 10 ... 70 mm2Rigid Cu-Cable 2 x 10 ... 95 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/2CMT2020-006118 |
maximum operating voltage ul/csa | Main Circuit 600 V |
short-circuit protective devices | gG Type Fuses 250 A |
data sheet, technical information | https://library.abb.com/d/1SBC100192C0206 |
rated operational power ac-3 (pe) | (415 V) 75 kW(440 V) 90 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 37 kW |
idea granular category code (igcc) | 4755 >> Contactors |
rated control circuit voltage (uc) | 50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V |
rated operational current ac-1 (ie) | (690 V) 40 °C 200 A(690 V) 60 °C 175 A(690 V) 70 °C 160 A |
rated operational current ac-3 (ie) | (415 V) 55 °C 140 A(440 V) 55 °C 140 A(380 / 400 V) 55 °C 140 A(220 / 230 / 240 V) 55 °C 140 |
connecting capacity auxiliary circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 2x0.75 ... 2.5 mm2Solid 2 x 1 ... 4 mm2Stranded 2 x 1 .... 4 mm2 |
maximum electrical switching frequency | (AC-1) 300 cycles per hour |
maximum mechanical switching frequency | 300 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | Main Circuit 8 kV |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A |
rated short-time withstand current low voltage (icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A |
We use cookies