Product type: AF190B-30-22-11

AF190B-30-22-11 Contactor

Description

The AF190B-30-22-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 90 kW / 400 V AC (AC-3) or 125 hp / 480 V UL and switching power circuits up to 275 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Block Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 1SFL487063R1122.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight2.4 KG / psc.
Commodity number85364900
Country of originSE
Dimensions (WxHxD)105x196x153 mm
EAN code7320500511305
Product groupSS
eclassV11.0 : 27371003
etim 4EC000066 - Magnet contactor, AC-switching
etim 5EC000066 - Magnet contactor, AC-switching
etim 6EC000066 - Power contactor, AC switching
etim 7EC000066 - Power contactor, AC switching
etim 8EC000066 - Power contactor, AC switching
unspsc39121529
standardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
rohs statusFollowing EU Directive 2011/65/EU
terminal typeMain Circuit: Bars
cb certificatehttps://library.abb.com/d/SE-82315
kc certificatehttps://library.abb.com/d/9AKK107046A9912
cqc certificatehttps://library.abb.com/d/CQC2014010304676685
cul certificatehttps://library.abb.com/d/20121023-E36588
eac certificatehttps://library.abb.com/d/9AKK107046A8618
coil consumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V·APull-in at Max. Rated Control Circuit Voltage DC 205 W
rohs informationhttps://library.abb.com/d/2CMT2015-005440
e-number (sweden)3210440
mechanical durability5 million
horsepower rating ul/csa(200 ... 208 V AC) Three Phase 50 hp(220 ... 240 V AC) Three Phase 60 hp(440 ... 480 V AC) Three Phase 125 hp(550 ... 600 V AC) Three Phase 150 hp
general use rating ul/csa(600 V AC) 250 A
number of main contacts nc0
number of main contacts no3
object classification codeQ
rated making capacity ac-310 x Ie AC-3
rated making capacity ac-3e12 x Ie AC-3e
rated breaking capacity ac-38 x Ie AC-3
rated breaking capacity ac-3e8.5 x Ie AC-3e
declaration of conformity - cehttps://library.abb.com/d/2CMT2015-005440
declaration of conformity - ccchttps://library.abb.com/d/2020980304001306
number of auxiliary contacts nc2
number of auxiliary contacts no2
declaration of conformity - ukcahttps://library.abb.com/d/2CMT2020-006124
data sheet, technical informationhttps://library.abb.com/d/1SBC100192C0204
rated operational power ac-3 (pe)(415 V) 90 kW(440 V) 110 kW(500 V) 90 kW(690 V) 132 kW(1000 V) 110 kW(380 / 400 V) 90 kW(220 / 230 / 240 V) 55 kW
idea granular category code (igcc)4755 >> Contactors
rated control circuit voltage (uc)50 Hz / 60 Hz 24 ... 60 VDC Operation 20 ... 60 V
rated operational power ac-3e (pe)(415 V) 90 kW(440 V) 110 kW(500 V) 90 kW(690 V) 132 kW(1000 V) 110 kW(380 / 400 V) 90 kW(220 / 230 / 240 V) 55 kW
rated operational current ac-1 (ie)(1000 V) 40 °C 250 A(1000 V) 55 °C 225 A(1000 V) 60 °C 225 A(1000 V) 70 °C 185 A(690 V) 40 °C 275 A(690 V) 55 °C 250 A(690 V) 60 °C 250 A(690 V) 70 °C 200 A
rated operational current ac-3 (ie)(415 V) 55 °C 190 A(440 V) 55 °C 190 A(500 V) 55 °C 135 A(690 V) 55 °C 135 A(1000 V) 55 °C 85 A(380 / 400 V) 55 °C 190 A(220 / 230 / 240 V) 55 °C 190
rated operational current dc-1 (ie)(100 V) 1 Pole, 40 °C 250 A(100 V) 1 Pole, 60 °C 250 A(100 V) 1 Pole, 70 °C 200 A(110 V) 2 Poles in Series, 40 °C 250 A(110 V) 2 Poles in Series, 60 °C 250 A(110 V) 2 Poles in Series, 70 °C 200 A(110 V) 3 Poles in Series, 40 °C 250 A(110 V) 3 Poles in Series, 60 °C 250 A(110 V) 3 Poles in Series, 70 °C 200 A(175 V) 2 Poles in Series, 40 °C 250 A(175 V) 2 Poles in Series, 60 °C 250 A(175 V) 2 Poles in Series, 70 °C 200 A(200 V) 2 Poles in Series, 40 °C 250 A(200 V) 2 Poles in Series, 60 °C 250 A(200 V) 2 Poles in Series, 70 °C 200 A(220 V) 3 Poles in Series, 40 °C 250 A(220 V) 3 Poles in Series, 60 °C 250 A(220 V) 3 Poles in Series, 70 °C 200 A(260 V) 3 Poles in Series, 40 °C 250 A(260 V) 3 Poles in Series, 60 °C 250 A(260 V) 3 Poles in Series, 70 °C 200 A(300 V) 3 Poles in Series, 40 °C 250 A(300 V) 3 Poles in Series, 60 °C 250 A(300 V) 3 Poles in Series, 70 °C 200 A(350 V) 4 Poles in Series, 40 °C 250 A(350 V) 4 Poles in Series, 60 °C 250 A(350 V) 4 Poles in Series, 70 °C 200 A(400 V) 4 Poles in Series, 40 °C 250 A(400 V) 4 Poles in Series, 60 °C 250 A(400 V) 4 Poles in Series, 70 °C 200 A(72 V) 1-Pole, 40 °C 250 A(72 V) 1-Pole, 60 °C 250 A(72 V) 1-Pole, 70 °C 200 A(72 V) 2 Poles in Series, 40 °C 250 A(72 V) 2 Poles in Series, 60 °C 250 A(72 V) 2 Poles in Series, 70 °C 200 A(72 V) 3 Poles in Series, 40 °C 250 A(72 V) 3 Poles in Series, 60 °C 250 A(72 V) 3 Poles in Series, 70 °C 200 A(90 V) 1 Pole, 40 °C 250 A(90 V) 1 Pole, 60 °C 250 A(90 V) 1 Pole, 70 °C 200 A
rated operational current dc-3 (ie)(110 V) 2 Poles in Series, 40 °C 250 A(110 V) 2 Poles in Series, 60 °C 250 A(110 V) 2 Poles in Series, 70 °C 200 A(110 V) 3 Poles in Series, 40 °C 250 A(110 V) 3 Poles in Series, 60 °C 250 A(110 V) 3 Poles in Series, 70 °C 200 A(220 V) 3 Poles in Series, 40 °C 250 A(220 V) 3 Poles in Series, 60 °C 250 A(220 V) 3 Poles in Series, 70 °C 200 A(72 V) 2 Poles in Series, 40 °C 250 A(72 V) 2 Poles in Series, 60 °C 250 A(72 V) 2 Poles in Series, 70 °C 200 A(72 V) 3 Poles in Series, 40 °C 250 A(72 V) 3 Poles in Series, 60 °C 250 A(72 V) 3 Poles in Series, 70 °C 200 A
rated operational current dc-5 (ie)(110 V) 2 Poles in Series, 40 °C 250 A(110 V) 2 Poles in Series, 60 °C 250 A(110 V) 2 Poles in Series, 70 °C 200 A(110 V) 3 Poles in Series, 40 °C 250 A(110 V) 3 Poles in Series, 60 °C 250 A(110 V) 3 Poles in Series, 70 °C 200 A(220 V) 3 Poles in Series, 40 °C 250 A(220 V) 3 Poles in Series, 60 °C 250 A(220 V) 3 Poles in Series, 70 °C 200 A(72 V) 2 Poles in Series, 40 °C 250 A(72 V) 2 Poles in Series, 60 °C 250 A(72 V) 2 Poles in Series, 70 °C 200 A(72 V) 3 Poles in Series, 40 °C 250 A(72 V) 3 Poles in Series, 60 °C 250 A(72 V) 3 Poles in Series, 70 °C 200 A
rated operational current ac-3e (ie)(415 V) 60 °C 190 A(440 V) 60 °C 190 A(500 V) 60 °C 135 A(690 V) 60 °C 135 A(1000 V) 60 °C 85 A(380 / 400 V) 60 °C 190 A(220 / 230 / 240 V) 60 °C 190 A
maximum mechanical switching frequency300 cycles per hour
rated short-time withstand current low voltage (icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A

We use cookies

This website collects cookies to deliver better user experience. By using our website, you agree to the use of cookies.

Find out how we use cookies.

We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: