Product type: AF370-40-22-13
AF370-40-22-13 Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 5.7 KG / psc. |
Commodity number | 85364900 |
Country of origin | SE |
Dimensions (WxHxD) | 184x225x180 mm |
EAN code | 7320500504406 |
Product group | SC |
eclass | V11.0 : 27371003 |
etim 4 | EC000066 - Magnet contactor, AC-switching |
etim 5 | EC000066 - Magnet contactor, AC-switching |
etim 6 | EC000066 - Power contactor, AC switching |
etim 7 | EC000066 - Power contactor, AC switching |
etim 8 | EC000066 - Power contactor, AC switching |
unspsc | 39121529 |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
operate time | Between Coil De-energization and NO Contact Opening 45 ... 80 msBetween Coil Energization and NO Contact Closing 30 ... 60 ms |
terminal type | Main Circuit: Bars |
bv certificate | https://library.abb.com/d/BV_36353_A0BV |
cb certificate | https://library.abb.com/d/SE-89316 |
lr certificate | https://library.abb.com/d/LR_14_70011(E1) |
abs certificate | https://library.abb.com/d/14-LD1092198-PDA |
cqc certificate | https://library.abb.com/d/CQC2014010304676670 |
cul certificate | https://library.abb.com/d/20140910-E73397 |
eac certificate | https://library.abb.com/d/9AKK107046A8618 |
prs certificate | https://library.abb.com/d/TE_2092_880423_16 |
coil consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·AHolding at Max. Rated Control Circuit Voltage DC 4.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·APull-in at Max. Rated Control Circuit Voltage DC 410 W |
rina certificate | https://library.abb.com/d/ELE060313XG_002 |
rmrs certificate | https://library.abb.com/d/9AKK107045A6978 |
rohs information | https://library.abb.com/d/2CMT2015-005439 |
dimension diagram | https://library.abb.com/d/1SFB535001G1123 |
dnv gl certificate | https://library.abb.com/d/DNV_E-14043 |
e-number (finland) | 3707251 |
rated frequency (f) | Main Circuit 60 Hz |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
coil operating limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
mechanical durability | 5 million |
ambient air temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... +70 °C |
general use rating ul/csa | (600 V AC) 420 A |
maximum breaking capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A |
rated operational voltage | Main Circuit 1000 V |
number of main contacts nc | 0 |
number of main contacts no | 4 |
object classification code | Q |
rated making capacity ac-3 | 10 x Ie AC-3 |
rated breaking capacity ac-3 | 8 x Ie AC-3 |
rated insulation voltage (ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
declaration of conformity - ce | https://library.abb.com/d/2CMT2015-005439 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001305 |
number of auxiliary contacts nc | 2 |
number of auxiliary contacts no | 2 |
connecting capacity main circuit | Flexible 2 x 70 ... 185 mm2Rigid Al-Cable 1 x 185 ... 240 mm2Rigid Cu-Cable 2 x 70 ... 185 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/2CMT2020-006118 |
maximum operating voltage ul/csa | Main Circuit 1000 V |
short-circuit protective devices | gG Type Fuses 630 A |
data sheet, technical information | https://library.abb.com/d/1SBC100192C0206 |
rated operational power ac-3 (pe) | (415 V) 200 kW(440 V) 200 kW(380 / 400 V) 200 kW(220 / 230 / 240 V) 110 kW |
idea granular category code (igcc) | 4755 >> Contactors |
rated control circuit voltage (uc) | 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V |
rated operational current ac-1 (ie) | (1000 V) 40 °C 400 A(1000 V) 60 °C 350 A(1000 V) 70 °C 290 A(690 V) 40 °C 525 A(690 V) 60 °C 425 A(690 V) 70 °C 350 A |
rated operational current ac-3 (ie) | (415 V) 55 °C 370 A(440 V) 55 °C 370 A(380 / 400 V) 55 °C 370 A(220 / 230 / 240 V) 55 °C 370 |
connecting capacity auxiliary circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 2x0.75 ... 2.5 mm2Solid 1 x 1 ... 4 mm2Stranded 1 x 1 .... 4 mm2 |
maximum electrical switching frequency | (AC-1) 300 cycles per hour |
maximum mechanical switching frequency | 300 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | Main Circuit 8 kV |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 525 A |
rated short-time withstand current low voltage (icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A |
We use cookies
This website collects cookies to deliver better user experience. By using our website, you agree to the use of cookies.