Product type: GAF750-10-11-70
GAF750-10-11 100-250V 50/60Hz / 100-250V DC Contactor
Description
Contact Person |
---|
Thomas Hoffmann |
+49 305 201 4443 ext. 1 |
sales@zwodltd.com |
Payment |
---|
Worldwide shipping |
---|
Additional Information |
---|
Price: Please send request |
Request Lead Time: ca. 1-2 Days |
Delivery Time: By Agreement |
Delivery Terms: FCA Berlin individually for each client according to INCOM TERMS 2022 |
Product Attribute | Attribute Value |
---|---|
Weight | 14 KG / psc. |
Commodity number | 85364900 |
Country of origin | SE |
Dimensions (WxHxD) | 210x283x242 mm |
EAN code | 7320500408803 |
Product group | SC |
eclass | V11.0 : 27371018 |
etim 4 | EC002552 - Power contactor, DC switching |
etim 5 | EC002552 - Power contactor, DC switching |
etim 6 | EC002552 - Power contactor, DC switching |
etim 7 | EC002552 - Power contactor, DC switching |
etim 8 | EC002552 - Power contactor, DC switching |
unspsc | 39121529 |
rohs status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
terminal type | Main Circuit: Bars |
cb certificate | https://library.abb.com/d/SEMKO_SE-70018 |
cqc certificate | https://library.abb.com/d/CQC2013010304595900 |
cul certificate | https://library.abb.com/d/20130524-E73397 |
eac certificate | https://library.abb.com/d/9AKK107046A8618 |
ul listing card | https://library.abb.com/d/UL_E73397 |
coil consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 4.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 850 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 850 V·APull-in at Max. Rated Control Circuit Voltage DC 950 V·A |
rohs information | https://library.abb.com/d/2CMT003517 |
dimension diagram | https://library.abb.com/d/53540919-60 |
e-number (finland) | 3709746 |
degree of protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
coil operating limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
mechanical durability | 3 million |
ambient air temperature | Operation -40 ... +80 °CStorage -40 ... +70 °C |
environmental information | https://library.abb.com/d/1SFC101066D0201 |
general use rating ul/csa | (1000 V DC) 900 A(440 V DC) 900 A(600 V DC) 900 A |
rated operational voltage | Main Circuit 1000 V |
number of main contacts nc | 0 |
number of main contacts no | 1 |
object classification code | Q |
rated insulation voltage (ui) | acc. to UL/CSA 1000 V |
declaration of conformity - ce | https://library.abb.com/d/2CMT003517 |
declaration of conformity - ccc | https://library.abb.com/d/2020980304001858 |
number of auxiliary contacts nc | 1 |
number of auxiliary contacts no | 1 |
connecting capacity main circuit | Bar 52 mm2Rigid Al-Cable 300 mm2Rigid Cu-Cable 300 mm2 |
declaration of conformity - ukca | https://library.abb.com/d/2CMT2020-006118 |
maximum operating voltage ul/csa | Main Circuit 600 V |
data sheet, technical information | https://library.abb.com/d/1SBC100192C0206 |
idea granular category code (igcc) | 4763 >> Power contactor, DC switching |
rated control circuit voltage (uc) | 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V |
rated operational current dc-1 (ie) | (1000 V) 3 Poles in Series, 40 °C 1050 A(1000 V) 3 Poles in Series, 55 °C 875 A(1000 V) 3 Poles in Series, 70 °C 720 A(220 V) 3 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 55 °C 875 A(220 V) 3 Poles in Series, 70 °C 720 A(400 V) 3 Poles in Series, 40 °C 1050 A(400 V) 3 Poles in Series, 55 °C 875 A(400 V) 3 Poles in Series, 70 °C 720 A(600 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 55 °C 875 A(600 V) 3 Poles in Series, 70 °C 720 A |
connecting capacity auxiliary circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm2Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm2Flexible 2x0.75 ... 2.5 mm2Solid 2 x 1 ... 4 mm2Stranded 2 x 1 .... 4 mm2 |
maximum mechanical switching frequency | 300 cycles per hour |
maximum operating altitude permissible | Without Derating 3000 m |
rated impulse withstand voltage (uimp) | Main Circuit 8 kV |
resistance to shock acc. to iec 60068-2-27 | Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g |
conventional free-air thermal current (ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A |