Product type: S804U-PVS5

S804U-PVS5 High Performance MCB

Description

The S804U-PVS5 is a 4-pole High Performance Circuit Breaker with cage terminal and a rated current of 5A. This is device is developed to meet the requirements as GFDI (Ground Fault Detection Interrupteur) in photovoltaic systems. The rated voltage is 1000V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S80U-PVS5 complies with UL489B and allows the use in photovoltaics in U.S.. The extensive range of accessory makes the use of S804U-PVS5 more comfortable. Due to the fast arc extinction of S804U-PVS5 your application will be secured.
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • High Performance Circuit Breakers HPCBs
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 2CCP824017R1159.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight980 G / psc.
Commodity number85362010
Country of originSwitzerland (CH)
Dimensions (WxHxD)108x142x82.5 mm
EAN code7612271419929
Product groupAF
cn885362020
eclassV11.0 : 27141901
etim 7EC000042 - Miniature circuit breaker (MCB)
etim 8EC000042 - Miniature circuit breaker (MCB)
remarksConnection from top and bottomConnecting with CU onlyIP40 in enclosure with coverCage terminal with captive screw
standardsUL 489B
power loss7.2 Wat Rated Operating Conditions per Pole 1.8 W
rohs statusFollowing EU Directive 2011/65/EU
release typeB
frequency (f)0...0 Hz
terminal typeScrew Terminals
weee category5. Small Equipment (No External Dimension More Than 50 cm)
weee b2c / b2bBusiness To Business
number of poles4
actuator markingI / O
housing materialInsulation group I, RAL 7035
pollution degree3
rohs informationhttps://library.abb.com/d/2CCC413009D0201, https://library.abb.com/d/9AKK107680A3903
mounting positionAny
tightening torque3.5 N·m
eplan catalog treeElectrical engineering / Protection devices / General
input voltage typeDC
product net length82.5 mm
rated current (in)5 A
rated voltage (ur)acc. to UL489B 1000 V DC
ambient temperature-25...60 °C
built-in depth (t2)82.5 mm
connecting capacityFlexible 0...50 mm2Rigid 0...70 mm2
rated frequency (f)0 ... 0 Hz
degree of protectionIP20
mounting on din railTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
overvoltage categoryIV
accessories availableYes
energy limiting class3
ambient air temperatureOperation -25...60 °C
tripping characteristicB
recommended screw driverPozidriv 2
environmental informationhttps://library.abb.com/d/2CCY413207D0203
number of protected poles4
rated operational voltage1000 V DC
object classification codeF
contact position indicationON / OFF / TRIP
rated short-circuit capacity(400 V) 2.5 kA(230 V) 2.5 kA
rated insulation voltage (ui)acc. to IEC/EN 60664-1 1500 V
declaration of conformity - cehttps://library.abb.com/d/2CCC413009D0201
rated operational current (ie)5 A
data sheet, technical informationhttps://library.abb.com/d/2CCC413003C0208
interrupting rating acc. to ul489(1000 V DC) 3 kA
width in number of modular spacings6
rated impulse withstand voltage (uimp)8 kV
rated conditional short-circuit current (inc)(230 V) 4 kA(400 V) 4 kA
rated ultimate short-circuit breaking capacity (icu)(230 V) 4 kA(400 V) 4 kA

We use cookies