Weight | 0.2 KG / psc. |
Commodity number | 85363010 |
Country of origin | Italy (IT) |
Dimensions (WxHxD) | 0.035x0.085x0.069 m |
EAN code | 8012542061717 |
Product group | AM |
cn8 | 85363010 |
eclass | V11.0 : 27142207 |
etim 7 | EC000905 - Earth leakage circuit breaker |
etim 8 | EC000905 - Earth leakage circuit breaker |
standards | IEC/EN 61009-1, IEC/EN 61009-2-1 |
cable size | 25 mm2 |
power loss | 2.5 W |
eplan macro | 9AKK107680A0597 |
housing type | Insulation group I - II, RAL 7035 |
release type | K |
actuator type | Toggle - Insulation group II, Black RAL 9005,sealable in ON-OFF positions |
frequency (f) | 50/60 Hz |
mounting type | on DIN rail EN 60715 (35mm) by means of mounting clip |
terminal type | Screw Terminals |
weee category | 5. Small Equipment (No External Dimension More Than 50 cm) |
accessory type | Auxiliary contactSignal contact / auxiliary contactShunt tripAuxiliary contact for bottom fittingUndervoltage releaseOvervoltage releaseMotor operating device |
cb certificate | https://library.abb.com/d/9AKK107492A6060 |
weee b2c / b2b | Business To Consumer |
number of poles | 2 |
fault indication | Blue flag on toggle |
pollution degree | 2 |
rohs information | https://library.abb.com/d/2CSC422002K2701 |
e-number (sweden) | 2100525 |
mounting position | Any |
test voltage (ut) | 110 ... 264 V |
tightening torque | 2.8 N·m |
eplan catalog tree | Electrical engineering / Protection devices / Ground fault current circuit breaker |
input voltage type | AC |
rated current (in) | 13 A |
rated voltage (ur) | 230 V |
ambient temperature | -25...55 °C |
built-in depth (t2) | 69 mm |
connecting capacity | Busbar 10 ... 10 mm2Stranded 0.75 ... 25 mm2Flexible with Ferrule 0.75 ... 16 mm2Flexible 0.75 ... 16 mm2 |
number of batteries | 0 |
rated cross-section | 1 - Solid-Core 0.75-25 mm24 - Multi-Wired 0.75-16 mm2 |
rated frequency (f) | 50/60 Hz |
screw terminal type | Failsafe Bi-directional Cylinder-lift Terminal |
degree of protection | Terminals IP20Housing IP40 |
earthing switch type | Undelayed |
electrical endurance | 10000 cycle |
leakage current type | A |
overvoltage category | III |
accessories available | Yes |
energy limiting class | 3 |
öve certificate | https://library.abb.com/d/9AKK107492A6085 |
wire stripping length | 12 mm |
rated residual current | 10 mA |
ambient air temperature | Operation -25...55 °C |
dielectric test voltage | 2 kV |
power supply connection | Arbitrary |
tripping characteristic | K |
environmental conditions | 28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 % |
operating characteristic | Instantaneous |
type of residual current | A type |
environmental information | https://library.abb.com/d/2CSC422002K2701 |
number of protected poles | 1 |
rated operational voltage | 230 / 240 V AC |
object classification code | F |
contact position indication | Red ON / Green OFF |
mechanical endurance (nendu) | 20000 cycle |
position of neutral terminals | Right |
rated insulation voltage (ui) | 500 V |
declaration of conformity - ce | https://library.abb.com/d/9AKK106713A5588 |
data sheet, technical information | https://library.abb.com/d/9AKK107492A6187 |
reference ambient air temperature | 20 °C |
rated short-circuit capacity (icn) | 6 kA |
short-circuit current rating (sccr) | 0.01 A |
width in number of modular spacings | 2 |
rated impulse withstand voltage (uimp) | 4 kV |
number of modular spacings per din rail | 2 |
primary rated impulse withstand voltage | 4 kV |
resistance to shock acc. to iec 60068-2-27 | 25g / 2 shocks / 13 ms |
rated residual breaking capacity (iδm) | EN 61009-1 6000 AIEC 61009-1 6000 A |
rated conditional short-circuit current (inc) | 10 kA |
resistance to vibrations acc. to iec 60068-2-6 | 0.1 mm or 1 g - 20 cycles at 5...150...5 Hz |
rated service short-circuit breaking capacity (ics) | 7.5 kA |
rated ultimate short-circuit breaking capacity (icu) | 10 kA |
rated service short-circuit breaking capacity, in % of icu (ics) | 6 kA |