ABB

2CSR255188R1104

Product type: DS201T C10 A30

DS201T C10 A30 Residual Current Circuit Breaker with Overcurrent Protection

Description

The DS201T series RCBO is a 1P+N in two-modules device for the protection of end user single-phase circuits against overload and short-circuit currentsprotection against the effects of sinusoidal alternating earth fault currentsprotection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA). DS201T meets the demand of a device suitable for installation in rolling stock equipment.
  • Low Voltage Products and Systems
  • Modular DIN Rail Products
  • Residual Current Devices RCDs
  • Residual Current Circuit Breakers with Overcurrent Protection RCBO
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 2CSR255188R1104.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.182 KG / psc.
Commodity number85363010
Country of originItaly (IT)
Dimensions (WxHxD)0.035x0.085x0.069 m
EAN code8012542590019
Product groupAM
cn885363010
eclassV11.0 : 27142207
etim 7EC000905 - Earth leakage circuit breaker
etim 8EC000905 - Earth leakage circuit breaker
standardsIEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1
cable size25 mm2
power loss1.8 W
applicationTraction
eplan macro9AKK107680A2467
housing typeInsulation group I - II, RAL 7035
actuator typeToggle - Insulation group II, Black RAL 9005,sealable in ON-OFF positions
frequency (f)50/60 Hz
mounting typeon DIN rail EN 60715 (35mm) by means of mounting clip
terminal typeScrew Terminals
weee category5. Small Equipment (No External Dimension More Than 50 cm)
accessory typeAuxiliary contactSignal contact / auxiliary contactShunt tripAuxiliary contact for bottom fittingUndervoltage releaseOvervoltage releaseMotor operating device
cb certificatehttps://library.abb.com/d/9AKK107492A6060
weee b2c / b2bBusiness To Consumer
ccc certificatehttps://library.abb.com/d/9AKK107680A1640
eac certificatehttps://library.abb.com/d/9AKK107680A1556
number of poles2
fault indicationBlue flag on toggle
options providedSuitable for traction applications
pollution degree2
rohs informationhttps://library.abb.com/d/2CSC422002K2701
e-number (sweden)2160075
mounting positionAny
test voltage (ut)170 ... 264 V
tightening torque2.8 N·m
input voltage typeAC
rated current (in)10 A
rated voltage (ur)230 V AC
built-in depth (t2)35 mm
connecting capacityBusbar 10 ... 10 mm2Stranded 0.75 ... 25 mm2Flexible with Ferrule 0.75 ... 16 mm2Flexible 0.75 ... 16 mm2
number of batteries0
rated cross-section1 - Solid-Core 0.75 ... 25 mm24 - Multi-Wired 0.75 ... 16 mm2
rated frequency (f)50/60 Hz
screw terminal typeFailsafe Bi-directional Cylinder-lift Terminal
degree of protectionTerminals IP20Housing IP40
earthing switch typeUndelayed
electrical endurance10000 cycle
leakage current typeA
mechanical endurance20000 cycle
overvoltage categoryIII
accessories availableYes
energy limiting class3
wire stripping length12 mm
rated residual current30 mA
ambient air temperatureOperation -25 ... +55 °CStorage -40 ... +70 °C
dielectric test voltage2 kV
power supply connectionArbitrary
tripping characteristicC
environmental conditions28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 %
operating characteristicInstantaneous
type of residual currentA type
environmental informationhttps://library.abb.com/d/2CSC422002K2701
number of protected poles1
rated operational voltage230 V AC
object classification codeF
contact position indicationRed ON / Green OFF
rated short-circuit capacity6 kA
position of neutral terminalsRight
rated insulation voltage (ui)500 V
declaration of conformity - cehttps://library.abb.com/d/9AKK106713A5588
data sheet, technical informationhttps://library.abb.com/d/9AKK107492A6187
reference ambient air temperature30 °C
short-circuit current rating (sccr)0.03 A
width in number of modular spacings2
rated impulse withstand voltage (uimp)4 kV
number of modular spacings per din rail2
primary rated impulse withstand voltage4 kV
resistance to shock acc. to iec 60068-2-2725g 2 shocks 13 ms
rated residual breaking capacity (iδm)EN 61009-1 6000 AIEC 61009-1 6000 A
resistance to vibrations acc. to iec 60068-2-60.1 mm or 1 g - 20 cycles at 5...150...5 Hz
rated service short-circuit breaking capacity (ics)7.5 kA
rated ultimate short-circuit breaking capacity (icu)7.5 kA
rated service short-circuit breaking capacity, in % of icu (ics)6 kA

We use cookies