Product type: BC7-40-00-01

BC7-40-00-01 Mini Contactor 24VDC

Description

The BC7-40-00 mini contactor is a compact 4 pole contactor with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
  • Low Voltage Products and Systems
  • Control Products
  • Contactors
  • Mini Contactors
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on GJL1313201R0001.
  • ZWOD Vertriebs und Logistik GmbH carries 225191 items from ABB.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.175 KG / psc.
Commodity number85365080
Country of originDE
Dimensions (WxHxD)52.5x57.5x46.7 mm
EAN code4013614188831
Product groupSA
eclassV11.0 : 27371003
etim 4EC000066 - Magnet contactor, AC-switching
etim 5EC000066 - Magnet contactor, AC-switching
etim 6EC000066 - Power contactor, AC switching
etim 7EC000066 - Power contactor, AC switching
etim 8EC000066 - Power contactor, AC switching
unspsc39121529
standardsIEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1
power lossat Rated Operating Conditions AC-1 per Pole 1.4 W
rohs statusFollowing EU Directive 2011/65/EU
bv certificatehttps://library.abb.com/d/1SAA920000-0204
cb certificatehttps://library.abb.com/d/1SAA938000-2002
kc certificatehttps://library.abb.com/d/1SAA938000-1501
lr certificatehttps://library.abb.com/d/1SAA938000-0504
cqc certificatehttps://library.abb.com/d/CQC2003010304064033
eac certificatehttps://library.abb.com/d/1SAA920000-2702
number of poles4
rmrs certificatehttps://library.abb.com/d/1SAA938000-0704
rohs informationhttps://library.abb.com/d/1SAD938517-0001
culus certificatehttps://library.abb.com/d/cUL_E191658
dimension diagramhttps://library.abb.com/d/GJL1200436F0001
tightening torqueControl Circuit 0.8 ... 1.1 N·mMain Circuit 0.8 ... 1.1 N·m
dnv gl certificatehttps://library.abb.com/d/1SAA938000-0306
mini contactor typeMini Contactor
rated frequency (f)Control Circuit DCMain Circuit 60 HzMain Circuit 50 HzMain Circuit DC
degree of protectionControl Circuit Terminals IP20Main Circuit Terminals IP20
mounting on din railTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
coil operating limits(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
mechanical durability10000000 cycle
wire stripping lengthMain Circuit 9 mm
ambient air temperatureOperation -25 ... +55 °CStorage -40 ... +80 °C
full load amps motor use(115 V AC) Single Phase 13.8 A(200 V AC) Three Phase 7.8 A(220 ... 240 V AC) Three Phase 9.6 A(230 V AC) Single Phase 10 A(440 ... 480 V AC) Three Phase 7.6 A(550 ... 600 V AC) Three Phase 6.1 A
horsepower rating ul/csa(115 V AC) Single Phase 0.75 Hp(200 V AC) Three Phase 2 Hp(220 ... 240 V AC) Three Phase 3 Hp(230 V AC) Single Phase 1.5 Hp(440 ... 480 V AC) Three Phase 5 Hp(550 ... 600 V AC) Three Phase 5 Hp
tightening torque ul/csaControl Circuit 7 in·lbMain Circuit 7 in·lb
environmental informationhttps://library.abb.com/d/1SAC200068H0009
general use rating ul/csa(600 V AC) 16 A
rated operational voltageMain Circuit 690 V ACMain Circuit 220 V DC
number of main contacts nc0
number of main contacts no4
object classification codeQ
rated insulation voltage (ui)690 Vacc. to UL/CSA 600 V
declaration of conformity - cehttps://library.abb.com/d/1SAD938517-0001
declaration of conformity - ccchttps://library.abb.com/d/2020980304001854
number of auxiliary contacts nc0
number of auxiliary contacts no0
connecting capacity main circuitFlexible with Ferrule 1/2x 1 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm2Flexible 1/2x 1 ... 2.5 mm2Rigid 1/2x 1 ... 4 mm2
declaration of conformity - ukcahttps://library.abb.com/d/1SAD938501-1001
maximum operating voltage ul/csaMain Circuit 600 V AC
data sheet, technical informationhttps://library.abb.com/d/1SBC100214C0202
rated operational power ac-3 (pe)(230 V) Three Phase 3 kW(400 V) Three Phase 5.5 kW(500 V) Three Phase 5.5 kW(690 V) Three Phase, NO 3 kW
rated control circuit voltage (uc)24 V DC
connecting capacity control circuitFlexible with Ferrule 1/2x 1 ... 2.5 mm2Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm2Flexible 1/2x 1 ... 2.5 mm2Rigid 1/2x 1 ... 4 mm2
rated operational current ac-1 (ie)(220 / 240 V) 40 °C 20 A(220 / 240 V) 55 °C 16 A(380 / 440 V) 40 °C 20 A(380 / 440 V) 55 °C 16 A(690 V) 40 °C 6 A(690 V) 55 °C 6 A
maximum electrical switching frequency(AC-1) 300 cycles per hour(AC-3) 600 cycles per hour(DC-1) 600 cycles per hour(DC-3) 600 cycles per hour
maximum operating altitude permissible2000 m
rated impulse withstand voltage (uimp)Main Circuit 6 kV
connecting capacity main circuit ul/csaStranded 1/2x 22-10 AWG
resistance to shock acc. to iec 60068-2-2711 ms Pulse 15g
conventional free-air thermal current (ith)Main Circuit 20 A
resistance to vibrations acc. to iec 60068-2-65g / 5 ... 150 Hz
rated short-time withstand current low voltage (icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A

We use cookies

This website collects cookies to deliver better user experience. By using our website, you agree to the use of cookies.

Find out how we use cookies.

We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: