Weight | 0.35 KG / psc. |
Commodity number | 85389091 |
Country of origin | DE |
Dimensions (WxHxD) | 130x125.6x83.7 mm |
EAN code | |
Product group | 7023 |
ram | 128 MB |
approval | CE UKCA TÜV EAC (Eurasian) |
etim version | ETIM-7.0 |
gross weight | 410 |
purpose of u1 | Module supply |
purpose of u2 | Periphery supply |
type of uint1 | DC |
eclass version | ECLASS-9.1 |
plug-in memory | SD card |
terminal style | plug-in |
time deviation | +/- 10s/day |
tolerance of u2 | -30 %/+25 % |
purpose of uint1 | int. system voltage |
reach compliance | contains min. 1 SVHC-substance |
application range | Standard/failsafe |
multi programming | No |
supply voltage (v) | 24 24 |
tolerance of uint1 | -2 %/+3 % |
ambient temperature | -40 70 |
broad band noise to | EN 50125-3 |
connection terminal | Screw terminal Spring-loaded terminal |
emc to standard ... | EN 50121-4 EN 50121-3-2 |
etim reference group | EG000024 |
overvoltage category | OV2 |
power consumption dc | 16 |
supply voltage 2 (v) | 24 24 |
iec 61131 programming | No |
non-volatile variables | No |
safetynet p cycle time | 2 ... 60 000 ms |
condensation permitted? | Briefly |
eclass reference feature | 27242207 |
flex. cond. c/s awg info | 24 - 12 AWG |
protection type standard | EN 60529 |
type of supply voltage u1 | DC |
type of supply voltage u2 | DC |
uint1 short circuit proof | Yes |
perm. operating height asl | 2000 m |
ambient temp. to standard 2 | -40 ... +70 °C |
ambient temp. to standard 3 | -40 ... +70 °C |
app. site standard1 railway | EN 50125-3 |
app. site standard2 railway | EN 61373 |
climatic suitability to ... | EN 60068-2-30 EN 60068-2-2 EN 60068-2-1 EN 50155 EN 60068-2-78 EN 60068-2-14 |
freq. broadband noise, rail | 5 ... 150 Hz |
safetynet transmission rate | 100 MBit/s |
accel. broadband noise, rail | 0.572 g RMS |
acceleration broadband noise | 0.23 g RMS |
ambient temperature standard | EN 50155 |
connector type safetynet i/f | RJ45 |
setting safetynet trans.rate | Automatic |
standard 2 for ambient temp. | EN 50125-1 |
standard 3 for ambient temp. | EN 50125-3 |
standard1 b/band noise, rail | EN 61373 |
clearance & creepage dist. to | EN 50124-1 |
potential isolation 1 between | Periphery and module supply |
potential isolation 2 between | Periphery supply & system V. |
type of potential isolation 1 | Functional insulation |
type of potential isolation 2 | Functional insulation |
weee classifikation (08/2018) | 5 devices (feed size < 50cm) |
app. site to standard1 railway | Track area (1m - 3m) |
app. site to standard2 railway | Category 1, Class A + B |
housing material lower section | PC |
max. curr. contin. oper. uint1 | 2 |
pollution degree clear.&creep. | PD2 |