Description

PSSu, electronic module, failsafe, digital inputs and outputs, 1 input, 1 test pulse output 0.25 A, 1 output, 2 A, dual-pole, shortcircuit-proof, overload-proof, free from feedback, for railway applications.
  • Controller
  • I/O systems
  • PSSuniversal - I/O modules
  • PSSuniversal - safe I/O modules
Contact Person
Thomas Hoffmann
+49 305 201 4443 ext. 1
sales@zwodltd.com
Payment
Bank TransferVisaMastercardPayPal
Worldwide shipping
DHLUnited Parcel ServiceFedEx ExpressTNT ExpressDB Schenker
Additional Information
Price: Please send request
Request Lead Time: ca. 1-2 Days
Delivery Time: By Agreement
Delivery Terms: FCA Berlin
Infoindividually for each client according to INCOM TERMS 2022
  • ZWOD Vertriebs und Logistik GmbH specializes in hard-to-find parts. Please send request a quote and save on 315220.
  • ZWOD Vertriebs und Logistik GmbH carries 3973 items from Pilz.
Multiples Of: 1
Product Specifications
Product AttributeAttribute Value
Weight0.046 KG / psc.
Commodity number85389091
Country of originDE
Dimensions (WxHxD)12.6x76x60.2 mm
EAN code
Product group7017
approvalCE UKCA TÜV EAC (Eurasian)
etim versionETIM-7.0
gross weight46
eclass versionECLASS-9.1
terminal stylesteckbar
application rangeFail-safe
ambient temperature-40
broad band noise toEN 61373
dc voltage at input24 V DC
emc to standard ...EN 61000-6-2 EN 61000-4-4 EN 61000-4-5 EN 61000-6-4 EN 61000-4-6 EN 61000-4-2 EN 61000-4-3
dc voltage at output24 V DC
etim reference groupEG000024
overvoltage categoryOV2
housing material codePA
name of coding elementG
acc. shock to standard12g
acc. shock to standard25g
number 2-pin sc outputs1
colour of coding elementgelb
eclass reference feature27242604
number of digital inputs1
protection type standardEN 60529
protection type, housingIP20
protection type, mountingIP51
vibration to standard ...EN 50125-3
perm. operating height asl2000 m
pot. isolation 2pole s/c oja
potential isolation inputsja
ambient temp. to standard 2-40 ... +70 °C
ambient temp. to standard 3-40 ... +70 °C
app. site standard1 railwayEN 50125-3
app. site standard2 railwayEN 61373
climatic suitability to ...EN 50125-1 EN 60068-2-2 EN 60068-2-1 EN 50155 EN 60068-2-14 EN 50125-3
freq. broadband noise, rail5 ... 150 Hz
accel. broadband noise, rail0,79 g RMS
ambient temperature standardEN 50155
housing material front platePC
number of test pulse outputs1
standard 2 for ambient temp.EN 50125-1
standard 3 for ambient temp.EN 50125-3
standard1 b/band noise, railEN 61373
storage temperature standardEN 60068-2-1/-2
2pole s/c o short circ. proofja
clearance & creepage dist. toEN 50124-1
weee classifikation (08/2018)5 devices (feed size < 50cm)
app. site to standard1 railwayGleisbereich (1m - 3m)
app. site to standard2 railwayKategorie 1, Klasse A + B
housing material lower sectionPC
pollution degree clear.&creep.PD2

We use cookies

This website collects cookies to deliver better user experience. By using our website, you agree to the use of cookies.

Find out how we use cookies.

We’re sorry, our website no longer supports
For your security and a speedy zwod experience, please update your browser: