Weight | 4.5 KG / psc. |
Commodity number | 85044084 |
Country of origin | AT |
Dimensions (WxHxD) | 70x345x243 mm |
EAN code | |
Product group | 7074 |
approval | UL Listed CE UKCA TÜV EAC (Eurasian) |
cooling type | Built-on fan |
etim version | ETIM-7.0 |
gross weight | 5600 g |
purpose of u2 | supply |
eclass version | ECLASS-9.1 |
humidity class | 1K3 |
noise emission | 58 dB (A) |
power derating | 2.5 %/K |
humidity rating | 85 % r. h. |
housing material | Galvanised steel |
reach compliance | contains min. 1 SVHC-substance |
mounting position | vertical |
supply voltage (v) | 208 V |
ambient temperature | 0 °C |
emc to standard ... | EN 61800-3 |
peak current for 2 s | 18 A |
peak current for 5 s | 12 A |
supply voltage 2 (v) | 24 V |
number of sto-enables | 2 |
ambient temp. derating | 40 - 55 °C |
purpose of phase range | Mains supply |
condensation permitted? | Not permitted |
galv. isol. n/safe sc o | Yes |
power derating per 100m | 1.5 %/100 m |
tolerance u2 with brake | +15 % |
type of analogue inputs | Voltage |
eclass reference feature | 27023201 |
number of digital inputs | 4 |
protection type standard | EN 60529 |
ambient temperature class | 1K4 |
number of analogue inputs | 2 |
signal range analog input | -10 - 10 V |
type of supply voltage u1 | AC |
type of supply voltage u2 | DC |
vibration to standard ... | EN 60721-3-3 |
perm. operating height asl | 1000 m |
potential isolation inputs | yes |
signal level at input at 0 | -3 - +5 VDC |
storage temperature change | 20 K/h |
supply voltage with phases | 3 x 208…3 x 480 V |
tolerance u2 without brake | +15 % |
connector type rs rs232 i/f | 9-pin D-Sub male connector |
cont outp. curr. at 3x230 v | 6 A |
cont outp. curr. at 3x480 v | 6 A |
number of auxiliary outputs | 2 |
number of rs 232 interfaces | 1 |
ambient temperature standard | DIN EN 60721-3-3 |
connector type ethernet int. | RJ45 |
cont. outp. curr. at 3x208 v | 6 A |
max. switch-on frequency o/p | 30/h |
number of canopen interfaces | 1 |
storage temperature standard | DIN EN 60721-3-1 |
type of supply voltage range | AC |
u input to en 61131-2 type 1 | 24 V DC |
climatic suitability standard | DIN EN 60721-3-3 |
cont. out. current at 3x400 v | 6 A |
pulse frequ. inverted rectif. | 8 kHz |
resolution of analogue inputs | 16 Bit |
v range at intermediate circ. | 900 V DC |
weee classifikation (08/2018) | 5 devices (feed size < 50cm) |
connector type encoder/incr.en | 15-pin D-Sub female connector |
perm. op. height at 1.5% derat | 1000 - 2500 m ASL |